Eveready C Red

Eveready C Red  is a carbon zinc (zinc chloride) primary battery designed for low-drain medical devices including blood pressure monitors, basic diagnostic equipment, and portable radios. Key specifications: 1.5V nominal voltage; average capacity of 1,100 mAh (rated at 25 mA continuous at 21°C to 0.8V cutoff); AA size; IEC R6 designation; ANSI 15D; zinc-manganese dioxide chemistry; operating temperature -18°C to 55°C (0°F to 130°F); average weight 15.0 grams; volume 8.0 cubic centimeters; and 3-year shelf life at 21°C . Features leak-resistant construction with guarantee based on IEC standard service tests, zero added mercury and cadmium, and Quality Seal for Trusted Power . For clinicians, this battery is indicated for low-drain medical equipment where cost-effective power is prioritised over high-drain performance, suitable for intermittent-use devices and backup equipment in clinic and home healthcare settings. WARNING: Keep away from small children. If swallowed, promptly see doctor; have doctor phone (202) 625-3333 collect.

Description

Eveready C Red 

PRIMARY USES

1. Reliable Power for Low-Drain Medical and Healthcare Equipment
Primary Use: Provides stable 1.5V DC power for low-drain medical devices including portable blood pressure monitors, basic patient assessment tools, digital thermometers, and other healthcare equipment with modest power requirements where cost-effective, single-use battery power is appropriate .
How it helps: For the clinical equipment manager and home healthcare provider, not all medical devices require high-drain alkaline batteries. Carbon zinc batteries are specifically designed for low-drain applications where the device draws minimal current over extended periods. The Eveready Super Heavy-Duty AA battery delivers 1.5V nominal voltage with an average capacity of 1,100 mAh using carbon zinc (zinc chloride) technology, which is well-suited for intermittent-use medical equipment that may sit idle between patient encounters. For the home healthcare patient using a basic blood pressure monitor or thermometer, this means a cost-effective power solution that provides reliable performance for the device’s intended use.
2. Three-Year Storage Life for Clinic Backup Equipment
Primary Use: Provides up to 3 years of shelf life at 21°C when not in use, making these batteries suitable for backup medical equipment, clinic supply rooms, and home healthcare kits where batteries are stored for extended periods before use .
How it helps: For the healthcare facility materials manager and home care coordinator, maintaining inventory of backup batteries for medical equipment requires products that retain power during storage. The Eveready Super Heavy-Duty AA battery holds power for up to 3 years in storage, ensuring batteries are ready when needed. This shelf life, while shorter than alkaline alternatives, is adequate for most healthcare inventory rotation schedules and makes these batteries a practical choice for clinics and home health agencies seeking cost-effective power solutions for backup equipment that receives intermittent use.
3. Leak-Resistant Construction for Sensitive Medical Equipment Protection
Primary Use: Features leak-resistant construction with a guarantee based on IEC standard service tests, designed to help protect sensitive medical equipment from corrosive battery leakage .
How it helps: For the biomedical engineer and clinical equipment manager, battery leakage in medical devices can cause costly damage and equipment downtime. The Eveready Super Heavy Duty AA battery is engineered with leak-resistant construction to help safeguard devices from corrosive damage . This feature is particularly important for medical equipment that may hold batteries for extended periods between uses. For the patient and healthcare provider, this provides added protection for valuable diagnostic and monitoring devices.
4. Zero Added Mercury for Environmentally Responsible Healthcare
Primary Use: Contains zero added mercury and zero added cadmium, complying with environmental regulations for disposal and reducing toxic exposure risk in healthcare settings .
How it helps: For the healthcare facility environmental safety officer, eliminating mercury and cadmium from batteries reduces hazardous waste disposal requirements and environmental impact. The Eveready Super Heavy Duty AA battery is manufactured with zero added mercury and cadmium . The carbon zinc chemistry (zinc-manganese dioxide with zinc chloride electrolyte) is free from added heavy metals. For the healthcare facility, this means simplified disposal procedures and reduced environmental footprint while maintaining cost-effective power for low-drain medical equipment.

SECONDARY USES

1. Powering portable radios and communication devices in healthcare facilities: For hospitals, clinics, and nursing homes, these batteries power portable two-way radios used by security staff, maintenance personnel, and clinical teams requiring reliable communication throughout the facility .
2. Operation of low-drain diagnostic equipment in remote clinics: For mobile health units and rural clinics with limited access to mains electricity, these batteries power basic diagnostic tools such as otoscopes, penlights, and other low-drain examination devices used in patient assessments .
3. Powering remote controls for medical equipment: For healthcare facilities and home care settings, these batteries power remote controls for hospital beds, adjustable chairs, entertainment systems, and basic environmental controls where cost-effective power is desired .
4. Operation of clocks and timing devices in clinical settings: Powers wall clocks, interval timers, and basic timing devices used in patient examination rooms, waiting areas, and staff stations where continuous, low-drain power is required .
5. Clinic supply room inventory and emergency preparedness kits: For healthcare facilities maintaining emergency supplies, the 3-year shelf life makes these batteries suitable for inclusion in disaster preparedness kits and clinic supply rooms where batteries are rotated regularly .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: Disposable, single-use, cylindrical primary battery, non-rechargeable 
  • Designation: Eveready Super Heavy Duty AA, Eveready Red AA, Eveready Carbon Zinc AA, Eveready 1015 
  • Manufacturer Series: Super Heavy Duty 
  • Chemical System: Zinc-Manganese Dioxide (Zn/MnO₂), also known as Carbon Zinc 
  • Key Components: Zinc can (anode), manganese dioxide (cathode), zinc chloride and/or ammonium chloride electrolyte, steel, paper, plastic
  • Unique Feature: Leak-resistant construction with guarantee; zero added mercury and cadmium; Quality Seal for Trusted Power; designed for low-drain applications; 3-year shelf life 

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Nominal Voltage: 1.5 volts 
  • Average Capacity: 1,100 mAh (rated at 25 mA continuous at 21°C to 0.8V cutoff) 
  • Physical Dimensions: Diameter 13.5-14.5 mm; Height 49.5-50.5 mm 
  • Average Weight: 15.0 grams (0.5 oz.) 
  • Volume: 8.0 cubic centimeters (0.5 cubic inch) 
  • Terminal Type: Raised positive, flat negative
  • Battery Size: AA
  • IEC Designation: R6 
  • ANSI Designation: 15D 
  • Chemistry Type: Carbon Zinc (Zinc-Chloride)
  • Operating Temperature: -18°C to 55°C (0°F to 130°F) 
  • Jacket: Metal 
  • Shelf Life: 3 years at 21°C (Ready to use for up to 3 years when not in use) 
  • Leakage Protection: Leak-resistant construction with guarantee based on IEC standard service tests 
  • Heavy Metals: Zero added mercury, zero added cadmium 
  • Quality Seal: Quality Seal for Trusted Power 

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Preparation: Remove from packaging. Check expiration date. No preparation required.
  • Usage Instructions: Insert battery matching polarity (+ and -) as indicated in device. Replace all batteries in a device at the same time. Do not mix old and new batteries. Do not mix different battery types or brands. Remove used batteries promptly. Best used in low-drain devices .
  • Storage Conditions: Store in a cool, dry, well-ventilated area. Elevated temperatures shorten battery life. Do not store in direct sunlight or near heat sources. Avoid storage in high-humidity environments.
  • Portion Size: One or more AA cells per device depending on voltage requirements.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Allergens: None. No latex. No known allergens in battery construction.
  • Ingestion Hazard: Immediate medical emergency. Swallowing a battery can be harmful. Contents of an open battery can cause serious chemical burns of mouth, esophagus, and gastrointestinal tract.
  • Battery Ingestion Hotline: Call 202-625-3333 collect day or night for battery ingestion.
  • Choking Hazard: AA batteries can lodge in the esophagus of infants and small children if swallowed. Keep out of reach of children.
  • Inhalation (leakage): Contents of an open battery can cause respiratory irritation. Provide fresh air and seek medical attention.
  • Skin Contact (leakage): Contents of an open battery can cause skin irritation and/or chemical burns. Remove contaminated clothing and wash skin with soap and water.
  • Eye Contact (leakage): Contents of an open battery can cause severe irritation and chemical burns. Immediately flush eyes thoroughly with water for at least 15 minutes. Seek medical attention.
  • Short Circuit: Do not short circuit terminals. Prolonged short circuit can cause battery to lose energy and generate heat.
  • Disposal: Contains no added mercury. Dispose in accordance with local regulations. Do not incinerate .
  • Applications: Low-drain medical devices, blood pressure monitors, basic diagnostic equipment, clocks, flashlights, radios, remote controls, smoke alarms .
  • Quality Assurance: Guaranteed against material and manufacturing defects.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store in cool, dry, well-ventilated area away from direct sunlight, heat sources, and humidity. Elevated temperatures result in shortened battery life.
  • Shelf Life: 3 years at 21°C. Check expiration date printed on package .
  • Inspection: Do not use batteries that are leaking, corroded, swollen, or have damaged packaging. Do not use expired batteries.
  • Handling: Do not install backwards. Do not short circuit terminals. Do not crush, puncture, or disassemble. Do not expose to fire or temperatures above manufacturer limits. Avoid damaging the label—it provides electrical insulation.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Battery ingestion: AA batteries are a serious ingestion hazard for infants and young children. If a battery is swallowed, seek immediate medical attention. Call the National Battery Ingestion Hotline at 202-625-3333 collect day or night for advice and follow-up.
  • Keep out of reach of children: Store batteries in original packaging or in a secure container that children cannot open. Keep new and used batteries out of reach of children at all times.
  • Do not ingest: Battery contains zinc chloride and manganese dioxide which are corrosive and toxic if ingested.
  • Do not install backwards: Reversing polarity can cause leakage, rupture, or fire. Inadvertent charging can occur if battery is installed backwards in a multi-cell configuration.
  • Do not charge: These batteries are not designed for recharging. Recharging can cause battery leakage, explosion, or fire.
  • Do not short circuit: Short circuit can cause the battery to lose energy and generate significant heat.
  • Do not disassemble, crush, puncture, or incinerate: The battery should not be opened or burned. Exposure to ingredients contained within or their combustion products could be harmful. The battery may explode if disposed of in fire.
  • Do not mix battery types: Do not mix old and new batteries, different brands, or different chemistries in the same device.
  • Do not expose to extreme heat: Do not place in fire, oven, microwave, or direct sunlight.
  • Replace all batteries at the same time: Replacing only some batteries can cause leakage or reduced performance.
  • Leakage precautions: If a battery leaks, avoid contact with skin, eyes, and clothing. Zinc chloride can cause burns. Ventilate area.

2. FIRST AID MEASURES

  • Ingestion: Do not induce vomiting. Do not give food or drink. Seek immediate medical attention. Call the National Battery Ingestion Hotline at 202-625-3333 collect day or night for advice and follow-up.
  • Eye contact (battery leakage): Contents of an open battery can cause severe irritation and chemical burns. If battery ruptures and contents contact eyes, rinse immediately with plenty of lukewarm water for a minimum of 15 minutes, lifting upper and lower lids. Get immediate medical attention.
  • Skin contact (battery leakage): Contents of an open battery can cause skin irritation and chemical burns. Wash skin with soap and water for at least 15 minutes. If irritation persists or burns are present, seek medical attention.
  • Inhalation (battery leakage): Contents of an open battery can cause respiratory irritation. Move to fresh air. If symptoms persist, seek medical attention.

3. FIRE FIGHTING MEASURES

  • Flammability: Carbon zinc batteries are combustible. Will burn if exposed to open flame.
  • Extinguishing Media: Use water spray, foam, dry chemical powder, or carbon dioxide (CO₂). It is permissible to use any class of extinguishing medium.
  • Fire Response: Cool exterior of batteries if exposed to fire to prevent rupture. For small fires, use an appropriate extinguisher. For large fires, evacuate the area. Do not throw batteries into fire as they may explode. Firefighters should wear self-contained breathing apparatus (SCBA) and full protective gear.